Support
AXM/AXL
Calibrating your truck scale
How to obtain an accurate calibration reading
Consider a 0.2% of margin of error between values.
Calibration Instructions
1. Set Tare Weigh – LO VALUE VEHICLE EMPTY
With the AXM201/202 display on:
– Press [P] button for 2 seconds to enter Program Mode (dECPT will appear on the display).
– Press [P] button twice to display LO, press once more to adjust the value.
– Adjust display value with [- ] and [ + ] buttons, until reading is the same as the weighbridge docket (known as Tare Weight)
– Press ⏎ button to store
– Press [⦶] button to exit program mode.
2. Set Max Weigh – HI VALUE VEHICLE LOADED
With the AXM201/202 display on:
– Press [P] button for 2 seconds to enter Program Mode (dECPT will appear on the display).
– Press I P 1 button 4 times to display HI, press once more to adjust the value.
– Adjust display value with [- ] and [ + ] buttons, until reading is the same as the weighbridge docket (known as Tare Weight)
– Press ⏎ button to store
– Press [⦶] button to exit program mode.
1. Set Tare Weigh – LO VALUE VEHICLE EMPTY
With the AXM201/202 display on:
– Press and hold [P] button until CHAN appears
– Press [P] again and -1- will appear (when setting weights for the first time stay on channel 1 until calibration for channel 1 is complete)
– Press [+] and channel -2- will appear (skip this step if you are calibrating channel 1)
– Press [P] again, the screen should say DECP
– Press [P] button twice to display LO, press once more to adjust the value.
– Adjust display value with [- ] and [ + ] buttons until reading is the same as the weighbridge docket (known as Tare Weight)
– Press ⏎ button to store
– Press and hold [P] until DECP appears
– Press [P] again and -1- appears.
– Use the [+] button to change to channel -2- and press ⏎
– Press the [P] again until you get to LO.
– Press [P] one more time until the weight appears
– Use the [+] and [-] buttons to set the scales to match the weighbridge docket, remembering you are now setting your rear axle or Drive weight.
– Press ⏎ button to store
– Press [⦶] button to exit program mode.
2. Set Max Weigh – HI VALUE VEHICLE LOADED
With the AXM201/202 display on:
Continue the steps above to complete the HI calibration
Video Instructions
*For single and dual channel configurations
Troubleshooting
Solution: Recalibrate “LO” value at unladen/empty weight and “HI” value at laden/full weight.
Solution: Recalibrate the “LO” value at minimum/empty weight and “HI” at maximum weight.
Solution:Keep the engine running to provide air to the suspension system. Park the trailer on the level ground. Release trailer brakes. Exhaust the air from the suspension and inflate to correct ride height.
Probable cause: The gauge is not connected to the air-bag suspension.
Solution:Check the air-line connection.
Solution: Set display auto OFF timer.
Solution: Adjust or increase display timer mode
Solution: Check the power circuit. If the voltage is below 8 DC the unit will not function correctly. Test the power source with a voltmeter. The gauge must be connected to a switched source to allow occasional software reboot.
Probable cause: Check if the polarity is correct
Solution: The red/brown wire must be connected to positive, and the black to negative.
Solution: The HCV is not functioning correctly, the air pressure applied to the suspension system could be inconsistent.
Probable Cause: The height control valve (HCV) cannot supply air to the suspension system.
Solution: Set unit into Pressure Gauge Mode to display actual air pressure). Then, check and replace ride height control valve.
Need Further Assistance?
Contact us on 1800 818 884 or use the form at the bottom of this page to email us.